- Overview
- Product Description
- Product Parameters
Basic Info.
Number of Charging Interfaces
One Pile with One Charge
Location
Home/Public
Installation
Wall Mounted/ Floor Mounted
Charge Method
Normal Charge
Full Protection
10 Protections
Warranty
2 Years
Transport Package
Wodden Case
Specification
378*258*165mm
Trademark
OEM
Origin
Guangdong, China
Product Description
Certificates:
CE ISO ROHS IEC TUV ETL
Charging Power:
3.5KW: 16A/AC220V ±15% 16A/AC240V±15%
7KW: 32A/AC220V±15% 32A/AC240V±15%
11KW: 16A/3phase AC380V±15% 50A/AC240V±15%
22KW: 32A/3phase AC380V±15%
Quantity of connectors:
1 connector
Safety
Overvoltage and undervoltage
Overload
Overcurrent
30ma AC and 6ma DC protection
PE protection
Temperature protection
Surge protection(optional)
Communication
Ethernet
Wifi (optional)
4g(optional)
OCPP1.6
Authentication via RFID or APP
Setting via PowerCore platform or screen
Material:
metal plate
Installation
Wallbox/Ground-mounted
Standards:
TYPE 1 / TYPE2 / GBT CHAdeMO
NO. | Parameters | Requirements | |||
General Requirements | |||||
1 | EV Charger Type | AC | |||
2 | Charger Capacity | 3.5KW | 7KW | 11KW | 22KW |
3 | Product Model NO. | ACB/L003P5A | ACB/L007A | ACB/L011A | ACB/L022A |
4 | Mounting | Wall-Mounted/Column Type | |||
Input Requirements | |||||
5 | AC Supply System | Single-Phase, 3 Wire AC system | Single-Phase, 3 Wire AC system(Type 1) Three-Phase, 5 Wire AC system(Type 2/GBT) | ||
6 | Nominal Input Voltage | AC220V±15%(Type 2/GBT) AC240V±15%(Type 1) | AC380V±15%(Type 2/GBT) AC240V±15%(Type 1) | AC380V±15% | |
7 | Input Frequency | 50/60±3Hz | |||
Environmental Requirements | |||||
8 | Ambient Temperature Range | -25 to 55°C | |||
9 | Ambient Humidity | 5 to 95% | |||
10 | Storage Temperature | -40 to 70°C | |||
Mechanical Requirements | |||||
11 | IP Ratings | IP 54 | |||
12 | Cooling | Natural Cooling | |||
Output Requirements | |||||
13 | Number of Outputs | 1 | |||
14 | Type of Each Output | AC220V±15%(Type 2/GBT) AC240V±15%(Type 1) | AC380V±15%(Type 2/GBT) AC240V±15%(Type 1) | AC380V±15% | |
15 | Single Output Max. Current | 16 Amp | 32 Amp | 16 Amp (Type 2/GBT) 50 Amp (Type 1) | 32 Amp |
User Interface & Display Requirements | |||||
16 | Display & Touch-Screen Size | 4.3 Inches Touch Screen | |||
17 | User Authentication | Mobile Application or User Interface / QR Code/RFID Card /Password Login | |||
18 | Metering Information | Consumption Units | |||
Communication Requirements | |||||
19 | Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | |||
20 | Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | |||
Protection & Safety Requirements | |||||
21 | Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772, etc. | |||
22 | Safety Parameters | Over Current, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |